View Featured Offers >>
7074
Anti-rabbit IgG, HRP-linked Antibody
Secondary Antibodies
Secondary Antibody

Anti-rabbit IgG, HRP-linked Antibody #7074

Citations (15443)
Filter:
  1. WB
After the primary antibody is bound to the target protein, a complex with HRP-linked secondary antibody is formed. The LumiGLO® is added and emits light during enzyme catalyzed decomposition.
To Purchase # 7074
Cat. # Size Qty. Price
7074P2
100 µl
7074S
1 ml
7074V
5 ml

Supporting Data

REACTIVITY
SENSITIVITY
MW (kDa)
Source/Isotype Goat 

Application Key:

  • WB-Western Blot
  • IP-Immunoprecipitation
  • IHC-Immunohistochemistry
  • ChIP-Chromatin Immunoprecipitation
  • C&R-CUT&RUN
  • C&T-CUT&Tag
  • DB-Dot Blot
  • eCLIP-eCLIP
  • IF-Immunofluorescence
  • F-Flow Cytometry

Species Cross-Reactivity Key:

  • H-Human
  • M-Mouse
  • R-Rat
  • Hm-Hamster
  • Mk-Monkey
  • Vir-Virus
  • Mi-Mink
  • C-Chicken
  • Dm-D. melanogaster
  • X-Xenopus
  • Z-Zebrafish
  • B-Bovine
  • Dg-Dog
  • Pg-Pig
  • Sc-S. cerevisiae
  • Ce-C. elegans
  • Hr-Horse
  • GP-Guinea Pig
  • Rab-Rabbit
  • All-All Species Expected

Product Description

Designed for use with rabbit polyclonal and monoclonal antibodies, this affinity purified goat anti-rabbit IgG (heavy and light chain) antibody is conjugated to horseradish peroxidase(HRP) for chemiluminescent detection.  This product is thoroughly validated with CST primary antibodies and will work optimally with the CST western immunoblotting protocol, ensuring accurate and reproducible results.

Product Usage Information

Recommended Antibody Dilutions:

1:1000–1:3000

20X LumiGLO® Reagent and 20X Peroxide #7003 1:1K–1:3K

SignalFireTM ECL Reagent #6883 1:1K–1:3K

SignalFireTM Plus ECL Reagent #12630 1:5K-1:15K

SignalFireTM Elite ECL Reagent #12757 1:10K-1:20K

Storage

Supplied in 10mM sodium HEPES (pH 7.5), 150 mM NaCl, 2 mg/ml bovine serum albumin (BSA) and 50% glycerol. Store at –20°C. Do not aliquot the antibodies. This product is stable for 60 months when stored at -20C.

Protocol

PRINT

View >Collapse >

12957 Western Blotting Application Solutions Kit Protocol

NOTE: Please refer to the primary antibody datasheet or product webpage for recommended primary antibody dilution buffer and recommended antibody dilution.

A. Solutions and Reagents

NOTE: Prepare solutions with reverse osmosis deionized (RODI) or equivalent grade water.

SUPPLIED REAGENTS

  1. 10X Cell Lysis Buffer: (#9803) To prepare 10 ml of 1X Cell Lysis Buffer: add 1 ml 10X Cell Lysis Buffer to 9 ml dH2O. Chill buffer on ice and add 50 µl 200X PMSF just prior to use.
  2. 200X PMSF: (#8553) Reconstitute 34.84 mg of lyophilized PMSF in 1 ml isopropyl alcohol, to make a 200 mM solution.
  3. 1X SDS Sample Buffer: Blue Loading Buffer Pack (#7722). Prepare fresh 3X reducing loading buffer by adding 1/10 volume 30X DTT (#14265) to 1 volume of 3X SDS loading buffer (#56036). Dilute to 1X with dH2O.
  4. Blue Prestained Protein Marker, Broad Range (11-250 kDa): (#59329).
  5. 10X Tris-Glycine SDS Running Buffer: (#4050) To prepare 1 L 1X running buffer: add 100 ml 10X Running Buffer to 900 ml dH2O, mix.
  6. 10X Tris-Glycine Transfer Buffer: (#12539) To prepare 1 L 1X transfer buffer: add 100 ml 10X Transfer Buffer to 200 ml methanol + 700 ml dH2O, mix.
  7. Nitrocellulose Sandwiches: (#12369).
  8. 10X Tris Buffered Saline with Tween® 20 (TBST): (#9997) To prepare 1 L 1X TBST: add 100 ml 10X TBST to 900 ml dH2O, mix.
  9. Nonfat Dry Milk: (#9999).
  10. Blocking Buffer: 1X TBST with 5% w/v nonfat dry milk; for 150 ml, add 7.5 g nonfat dry milk to 150 ml 1X TBST and mix well.
  11. Wash Buffer: 1X TBST.
  12. Bovine Serum Albumin (BSA): (#9998).
  13. Primary Antibody Dilution Buffer: 1X TBST with 5% BSA or 5% nonfat dry milk as indicated on primary antibody datasheet; for 20 ml, add 1.0 g BSA or nonfat dry milk to 20 ml 1X TBST and mix well.
  14. Secondary Antibody Conjugated to HRP: Anti-rabbit (#7074); anti-mouse (#7076).
  15. Detection Reagent: SignalFire™ ECL Reagent (#6883). Reagents A (#46935) and B (#74709) should be combined just prior to use.

ADDITIONAL REAGENTS (NOT SUPPLIED)

  1. Primary Antibody.
  2. 20X Phosphate Buffered Saline (PBS): (#9808) To prepare 1 L 1X PBS: add 50 ml 20X PBS to 950 ml dH2O, mix.
  3. Reverse Osmosis Deionized (RODI) Water.
  4. Isopropyl Alcohol.
  5. BCA Protein Assay Kit: (#7780) (OPTIONAL).
  6. Biotinylated Protein Ladder Detection Pack: (#7727) (OPTIONAL).
  7. Methanol.
  8. 10X Tris Buffered Saline (TBS): (#12498) To prepare 1 L 1X TBS: add 100 ml 10X to 900 ml dH2O, mix. (OPTIONAL).
  9. Streptavidin-HRP: (#3999) (if necessary).

B. Protein Blotting

A general protocol for sample preparation.

  1. Treat cells by adding fresh media containing regulator for desired time.
  2. Aspirate media from cultures; wash cells with 1X PBS; aspirate. If performing protein concentration quantification, proceed to step #3, if not, skip to step #8.
  3. Lyse cells by adding 1X Cell Lysis Buffer (80 µl per well of 6-well plate or 400 µl for a 10 cm diameter plate). Incubate plate on ice for 5 min, then scrape cells off the plate and transfer lysate to a microcentrifuge tube. Keep on ice.
  4. Sonicate for 10–15 sec to complete cell lysis and shear DNA (to reduce sample viscosity). Keep on ice.
  5. Centrifuge extract for 10 min at 14,000 x g in a cold microcentrifuge. Transfer supernatant to a new tube and discard pellet.
  6. Determine protein concentration using BCA Protein Assay Kit #7780.
  7. Add 3X SDS Sample Buffer to a final concentration of 1X. Proceed to step #10.
  8. Lyse cells by adding 1X SDS sample buffer (100 µl per well of 6-well plate or 500 µl for a 10 cm diameter plate). Immediately scrape the cells off the plate and transfer the extract to a microcentrifuge tube. Keep on ice.
  9. Sonicate for 10–15 sec to complete cell lysis and shear DNA (to reduce sample viscosity). Keep on ice.
  10. Heat a 20 µl sample to 95–100°C for 5 min; cool on ice.
  11. Microcentrifuge for 5 min.
  12. Prepare electrophoresis gel and apparatus using 1X running buffer.
  13. Load 15 µl onto SDS-PAGE gel (10 cm x 10 cm).

    NOTE: Loading of prestained molecular weight markers (#59329, 5 µl/lane) to verify electrotransfer and biotinylated protein ladder (#81851, 10 µl/lane) to determine molecular weights are recommended.

  14. Perform electrotransfer to nitrocellulose membrane (#12369) using 1X transfer buffer in a tank (wet) transfer system.

C. Membrane Blocking and Antibody Incubations

NOTE: Volumes are for 10 cm x 10 cm (100 cm2) or smaller membrane; for larger membranes, adjust volumes accordingly.

I. Membrane Blocking

  1. (Optional) After transfer, wash nitrocellulose membrane with 25 ml TBS for 5 min at room temperature.
  2. Incubate membrane in 25 ml of blocking buffer for 1 hr at room temperature.
  3. Wash three times for 5 min each with 15 ml of TBST.

II. Primary Antibody Incubation

Proceed to one of the following specific set of steps depending on the primary antibody used.

For Unconjugated Primary Antibodies

  1. Incubate membrane and primary antibody (at the appropriate dilution and diluent as recommended in the product datasheet) in 10 ml primary antibody dilution buffer with gentle agitation overnight at 4°C.
  2. Wash three times for 5 min each with 15 ml of TBST.
  3. Incubate membrane with the species appropriate HRP-conjugated secondary antibody (#7074 or #7076 at 1:2000) and, if necessary, anti-biotin, HRP-linked Antibody (#7075 at 1:1000–1:3000) to detect biotinylated protein markers in 10 ml of blocking buffer with gentle agitation for 1 hr at room temperature.
  4. Wash three times for 5 min each with 15 ml of TBST.
  5. Proceed with detection (Section D).

For HRP Conjugated Primary Antibodies

  1. Incubate membrane and primary antibody (at the appropriate dilution as recommended in the product datasheet) in 10 ml primary antibody dilution buffer with gentle agitation overnight at 4°C.
  2. Wash three times for 5 min each with 15 ml of TBST.
  3. If necessary, incubate with Anti-biotin, HRP-linked Antibody (#7075 at 1:1000–1:3000), to detect biotinylated protein markers, in 10 ml of blocking buffer with gentle agitation for 1 hr at room temperature.
  4. Wash three times for 5 min each with 15 ml of TBST.
  5. Proceed with detection (Section D).

For Biotinylated Primary Antibodies

  1. Incubate membrane and primary antibody (at the appropriate dilution as recommended in the product datasheet) in 10 ml primary antibody dilution buffer with gentle agitation overnight at 4°C.
  2. Wash three times for 5 min each with 15 ml of TBST.
  3. Incubate membrane with Streptavidin-HRP (#3999, not supplied) at 1:2000 in 10 ml of blocking buffer with gentle agitation for 1 hr at room temperature.
  4. Wash three times for 5 min each with 15 ml of TBST.
  5. Proceed with detection (Section D).
  6. Do not add Anti-biotin, HRP-linked Antibody for detection of biotinylated protein markers. There is no need. The Streptavidin-HRP will also visualize the biotinylated markers.

D. Detection of Proteins

  1. Incubate membrane in 10 ml SignalFire™ #6883 (5 ml Reagent A (#46935), 5 ml Reagent B (#74709)) with gentle agitation for 1 min at room temperature.
  2. Drain membrane of excess developing solution (do not let dry), wrap in plastic wrap and expose to x-ray film. An initial 10 sec exposure should indicate the proper exposure time.

    NOTE: Due to the kinetics of the detection reaction, signal is most intense immediately after incubation.

Protocol Id: 2064

Background

Chemiluminescence systems have emerged as the best all-around method for western blot detection. They eliminate the hazards associated with radioactive materials and toxic chromogenic substrates. The speed and sensitivity of these methods are unequalled by traditional alternatives, and because results are generated on film, it is possible to record and store data permanently. Blots detected with chemiluminescent methods are easily stripped for subsequent reprobing with additional antibodies. HRP-conjugated secondary antibodies are utilized in conjunction with specific chemiluminescent substrates to generate the light signal. HRP conjugates have a very high turnover rate, yielding good sensitivity with short reaction times.

Limited Uses

Except as otherwise expressly agreed in a writing signed by a legally authorized representative of CST, the following terms apply to Products provided by CST, its affiliates or its distributors. Any Customer's terms and conditions that are in addition to, or different from, those contained herein, unless separately accepted in writing by a legally authorized representative of CST, are rejected and are of no force or effect.

Products are labeled with For Research Use Only or a similar labeling statement and have not been approved, cleared, or licensed by the FDA or other regulatory foreign or domestic entity, for any purpose. Customer shall not use any Product for any diagnostic or therapeutic purpose, or otherwise in any manner that conflicts with its labeling statement. Products sold or licensed by CST are provided for Customer as the end-user and solely for research and development uses. Any use of Product for diagnostic, prophylactic or therapeutic purposes, or any purchase of Product for resale (alone or as a component) or other commercial purpose, requires a separate license from CST. Customer shall (a) not sell, license, loan, donate or otherwise transfer or make available any Product to any third party, whether alone or in combination with other materials, or use the Products to manufacture any commercial products, (b) not copy, modify, reverse engineer, decompile, disassemble or otherwise attempt to discover the underlying structure or technology of the Products, or use the Products for the purpose of developing any products or services that would compete with CST products or services, (c) not alter or remove from the Products any trademarks, trade names, logos, patent or copyright notices or markings, (d) use the Products solely in accordance with CST Product Terms of Sale and any applicable documentation, and (e) comply with any license, terms of service or similar agreement with respect to any third party products or services used by Customer in connection with the Products.

For Research Use Only. Not for Use in Diagnostic Procedures.
Cell Signaling Technology is a trademark of Cell Signaling Technology, Inc.
All other trademarks are the property of their respective owners. Visit our Trademark Information page.