View Featured Offers >>
31926
SignalStain® Boost IHC Detection Reagent (AP, Mouse)
Secondary Antibodies
Secondary Antibody

SignalStain® Boost IHC Detection Reagent (AP, Mouse) #31926

Citations (6)
Filter:
  1. IHC
Immunohistochemical analysis of paraffin-embedded human breast carcinoma using CD8α (C8/144B) Mouse mAb (IHC Specific) #70306 (red) and PD-L1 (E1L3N®) XP® Rabbit mAb #13684 (brown). SignalStain® Boost IHC Detection Reagent (AP, Mouse) and SignalStain® Vibrant Red Alkaline Phosphatase Substrate Kit #76713 were used to detect CD8α (C8/144B) Mouse mAb (IHC Specific). SignalStain® Boost IHC Detection Reagent (HRP, Rabbit) #8114 and SignalStain® DAB Substrate Kit #8059 were used to detect PD-L1 (E1L3N®) XP® Rabbit mAb.
Immunohistochemical analysis of paraffin-embedded human prostate carcinoma using CD8α (C8/144B) Mouse mAb (IHC Specific) #70306. Note: Detection was performed with SignalStain® Boost IHC Detection Reagent (AP, Mouse) and SignalStain® Vibrant Red Alkaline Phosphatase Substrate Kit #76713.
Immunohistochemical analysis of paraffin-embedded human tonsil using CD8α (C8/144B) Mouse mAb (IHC Specific) #70306 (red) and PD-L1 (E1L3N®) XP® Rabbit mAb #13684 (brown). SignalStain® Boost IHC Detection Reagent (AP, Mouse) and SignalStain® Vibrant Red Alkaline Phosphatase Substrate Kit #76713 were used to detect CD8α (C8/144B) Mouse mAb (IHC Specific). SignalStain® Boost IHC Detection Reagent (HRP, Rabbit) #8114 and SignalStain® DAB Substrate Kit #8059 were used to detect PD-L1 (E1L3N®) XP® Rabbit mAb.
To Purchase # 31926
Cat. # Size Qty. Price
31926S
15 ml

Supporting Data

REACTIVITY M
SENSITIVITY
MW (kDa)
Source/Isotype Horse 

Application Key:

  • WB-Western Blot
  • IP-Immunoprecipitation
  • IHC-Immunohistochemistry
  • ChIP-Chromatin Immunoprecipitation
  • C&R-CUT&RUN
  • C&T-CUT&Tag
  • DB-Dot Blot
  • eCLIP-eCLIP
  • IF-Immunofluorescence
  • F-Flow Cytometry

Species Cross-Reactivity Key:

  • H-Human
  • M-Mouse
  • R-Rat
  • Hm-Hamster
  • Mk-Monkey
  • Vir-Virus
  • Mi-Mink
  • C-Chicken
  • Dm-D. melanogaster
  • X-Xenopus
  • Z-Zebrafish
  • B-Bovine
  • Dg-Dog
  • Pg-Pig
  • Sc-S. cerevisiae
  • Ce-C. elegans
  • Hr-Horse
  • GP-Guinea Pig
  • Rab-Rabbit
  • All-All Species Expected

Product Description

SignalStain® Boost IHC Detection Reagent (AP, Mouse) is a ready-to-use solution intended for use in immunohistochemical assays to detect mouse primary antibodies. SignalStain® Boost IHC Detection Reagent (AP, Mouse) is a highly sensitive, one-step, polymer-based detection reagent that is specific for mouse IgG. It can be used to visualize targets in both paraffin-embedded and frozen tissue sections and it is compatible with all alkaline phosphatase-based substrates.

Product Usage Information

1. Equilibrate SignalStain® Boost IHC Detection Reagent (AP, Mouse) to room temperature prior to applying to the slides.

2. Cover sections with 1-3 drops (40-120 µl), as needed, and incubate in a humidified chamber for 30 minutes at room temperature.

3. Wash slides and develop with any alkaline phosphatase-compatible substrate.

Storage

SignalStain® Boost IHC Detection Reagent (AP, Mouse) should be stored at 4°C and is stable for 12 months.

Specificity / Sensitivity

SignalStain® Boost IHC Detection Reagent (AP, Mouse) can be used to detect mouse primary antibodies in immunohistochemical assays.

Species Reactivity:

Mouse

Limited Uses

Except as otherwise expressly agreed in a writing signed by a legally authorized representative of CST, the following terms apply to Products provided by CST, its affiliates or its distributors. Any Customer's terms and conditions that are in addition to, or different from, those contained herein, unless separately accepted in writing by a legally authorized representative of CST, are rejected and are of no force or effect.

Products are labeled with For Research Use Only or a similar labeling statement and have not been approved, cleared, or licensed by the FDA or other regulatory foreign or domestic entity, for any purpose. Customer shall not use any Product for any diagnostic or therapeutic purpose, or otherwise in any manner that conflicts with its labeling statement. Products sold or licensed by CST are provided for Customer as the end-user and solely for research and development uses. Any use of Product for diagnostic, prophylactic or therapeutic purposes, or any purchase of Product for resale (alone or as a component) or other commercial purpose, requires a separate license from CST. Customer shall (a) not sell, license, loan, donate or otherwise transfer or make available any Product to any third party, whether alone or in combination with other materials, or use the Products to manufacture any commercial products, (b) not copy, modify, reverse engineer, decompile, disassemble or otherwise attempt to discover the underlying structure or technology of the Products, or use the Products for the purpose of developing any products or services that would compete with CST products or services, (c) not alter or remove from the Products any trademarks, trade names, logos, patent or copyright notices or markings, (d) use the Products solely in accordance with CST Product Terms of Sale and any applicable documentation, and (e) comply with any license, terms of service or similar agreement with respect to any third party products or services used by Customer in connection with the Products.

For Research Use Only. Not for Use in Diagnostic Procedures.
Cell Signaling Technology is a trademark of Cell Signaling Technology, Inc.
E1L3N is a registered trademark of Cell Signaling Technology, Inc.
SignalStain is a registered trademark of Cell Signaling Technology, Inc.
XP is a registered trademark of Cell Signaling Technology, Inc.
All other trademarks are the property of their respective owners. Visit our Trademark Information page.